Published 1987 | Version v1
Book

Resolution limitations and optimization of the LLNL streak camera focus

  • 1. Lawrence Livermore National Lab., Univ. of California, P.O. Box 5508, L-473, Livermore, CA (USA)

Description

The RCA C73435 image tube is biased at voltages far from its original design in the LLNL ultrafast (10 ps) streak camera. Its output resolution at streak camera operating potentials has been measured as a function of input slit width, incident-light wavelength, and focus-grid voltage. The temporal resolution is insensitive to focus-grid voltage for a narrow (100 μm) input slit but is very sensitive to focused grid voltage for a wide (2 mm) input slit. At the optimum wide-slit focus voltage, temporal resolution is insensitive to slit width. Spatial resolution is nearly independent of focus-grid voltage for values that give good temporal resolution. Both temporal and spatial resolution depend on the incident-light wavelength. Data for 1.06-μm light show significantly better focusing than for 0.53 μm light. Streak camera operation is simulated with a computer program that calculates photoelectron trajectories. Electron ray tracing describes all of the observed effects of slit width, incident-light wavelength, and focus-grid voltage on output resolution

Additional details

Publishing Information

Publisher
SPIE Society of Photo-Optical Instrumentation Engineers.
Imprint Place
Bellingham, WA (USA)
Imprint Title
High speed photography, videography, and photonics V
Journal Page Range
vp.

Conference

Title
High speed photography, videography, and photonics V.
Dates
17-19 Aug 1987.
Place
San Diego, CA (USA).