Line pressure effects on differential pressure measurements

Description

The performance of differential pressure transducers in experimental pressurized water reactor (PWR) systems was evaluated. Transient differential pressure measurements made using a simple calibration proportionality relating differential pressure to output voltage could have large measurement uncertainties. A more sophisticated calibration equation was derived to incorporate the effects of zero shifts and sensitivity shifts as pressure in the pressure sensing line changes with time. A comparison made between the original calibration proportionality equation and the derived compensation equation indicates that potential measurement uncertainties can be reduced

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS., PC A02/MF A01 as DE82018716.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
9 p.
Report number
EGG-M--02482

Conference

Title
28. international instrumentation symposium.
Dates
3 - 6 May 1982.
Place
Las Vegas, NV (USA).

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
14725154
Subject category
S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
CALIBRATION; LOFT REACTOR; PERFORMANCE; PRESSURE GAGES; PRESSURE GRADIENTS; REACTOR INSTRUMENTATION; TRANSDUCERS
Descriptors DEC
MEASURING INSTRUMENTS; PWR TYPE REACTORS; REACTORS; RESEARCH AND TEST REACTORS; TANK TYPE REACTORS; TEST REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS