Published February 3, 1982
| Version v1
Report
Restricted
Line pressure effects on differential pressure measurements
Description
The performance of differential pressure transducers in experimental pressurized water reactor (PWR) systems was evaluated. Transient differential pressure measurements made using a simple calibration proportionality relating differential pressure to output voltage could have large measurement uncertainties. A more sophisticated calibration equation was derived to incorporate the effects of zero shifts and sensitivity shifts as pressure in the pressure sensing line changes with time. A comparison made between the original calibration proportionality equation and the derived compensation equation indicates that potential measurement uncertainties can be reduced
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS., PC A02/MF A01 as DE82018716.
Files
Additional details
Publishing Information
- Imprint Pagination
- 9 p.
- Report number
- EGG-M--02482
Conference
- Title
- 28. international instrumentation symposium.
- Dates
- 3 - 6 May 1982.
- Place
- Las Vegas, NV (USA).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 14725154
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- CALIBRATION; LOFT REACTOR; PERFORMANCE; PRESSURE GAGES; PRESSURE GRADIENTS; REACTOR INSTRUMENTATION; TRANSDUCERS
- Descriptors DEC
- MEASURING INSTRUMENTS; PWR TYPE REACTORS; REACTORS; RESEARCH AND TEST REACTORS; TANK TYPE REACTORS; TEST REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS
Optional Information
- Secondary number(s)
- CONF-820513--5.