Published August 2013 | Version v1
Journal article

Double prospectively ECG-triggered high-pitch spiral acquisition for CT coronary angiography: Initial experience

  • 1. Department of Cardiology, Chinese PLA General Hospital, Beijing (China)
  • 2. Department of Ultrasound, Chinese Armed Police General Hospital, Beijing (China)
  • 3. CT Research Collaboration, Healthcare Sector, Siemens Ltd, Beijing (China)

Description

Aim: To evaluate the feasibility of double prospectively electrocardiogram (ECG)-triggered high-pitch spiral acquisition mode (double high-pitch mode) for coronary computed tomography angiography (CTCA). Materials and methods: One hundred and forty-nine consecutive patients [40 women, 109 men; mean age 58.2 ± 9.2 years; sinus rhythm ≤70 beats/min (bpm) after pre-medication, body weight ≤100 kg] were enrolled for CTCA examinations using a dual-source CT system with 2 × 128 × 0.6 mm collimation, 0.28 s rotation time, and a pitch of 3.4. Double high-pitch mode was prospectively triggered first at 60% and later at 30% of the R–R interval within two cardiac cycles. Image quality was evaluated using a four-point scale (1 = excellent, 4 = non-assessable). Results: From 2085 coronary artery segments, 86.4% (1802/2085) were rated as having a score of 1, 12.3% (257/2085) as score of 2, 1.2% (26/2085) as score of 3, and none were rated as "non-assessable". The average image quality score was 1.15 ± 0.26 on a per-segment basis. The effective dose was calculated by multiplying the coefficient factor of 0.028 by the dose–length product (DLP); the mean effective dose was 3.5 ± 0.8 mSv (range 1.7–7.6 mSv). The total dosage of contrast medium was 78.7 ± 2.9 ml. Conclusion: Double prospectively ECG-triggered high-pitch spiral acquisition mode provides good image quality with an average effective dose of less than 5 mSv in patients with a heart rate ≤70 bpm

Availability note (English)

Available from http://dx.doi.org/10.1016/j.crad.2013.03.004

Additional details

Identifiers

DOI
10.1016/j.crad.2013.03.004;
PII
S0009-9260(13)00107-4;

Publishing Information

Journal Title
Clinical Radiology
Journal Volume
68
Journal Issue
8
Journal Page Range
p. 792-798
ISSN
0009-9260
CODEN
CLRAAG

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
45078625
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
BIOMEDICAL RADIOGRAPHY; COMPUTERIZED TOMOGRAPHY; CORONARIES; RADIATION DOSES
Descriptors DEC
ARTERIES; BLOOD VESSELS; BODY; CARDIOVASCULAR SYSTEM; DIAGNOSTIC TECHNIQUES; DOSES; MEDICINE; NUCLEAR MEDICINE; ORGANS; RADIOLOGY; TOMOGRAPHY

Optional Information

Copyright
Copyright (c) 2013 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.