Beta-NMR magnetic moment measurement using on-line mass separation and tilted foil polarization

  • 1. Rochester Univ., NY (USA). Nuclear Structure Research Lab.

Description

Tilted foil polarization and on-line mass separation have been successfully applied to a β-NMR technique for measuring nuclear moments. Nuclei are polarized using tilted carbon foils (multifoil array) and implanted in a catcher. Nuclear polarization, monitored by detection of anisotropic β-emission, is destroyed via resonant rf excitation to locate the NMR. Tests were performed using 12B (T1/2 = 20.4 ms, Iπ = 1+) and the ground-state magnetic moment of 33Cl (T1/2 = 2.51 s, Iπ = 3/2+) was measured using this arrangement. The 33Cl magnetic moment, corrected for diamagnetism, is μ = +0.7523(16) nm. (orig.)

Additional details

Publishing Information

Journal Title
Nucl. Instrum. Methods Phys. Res., Sect. A
Journal Volume
253
Journal Issue
2
Series
Nucl. Instrum. Methods Phys. Res., Sect. A.
Journal Page Range
256-263
ISSN
0168-9002
CODEN