Published March 2013
| Version v1
Journal article
Effect of beam emittance on chromatic blur for proton radiography
Creators
- 1. Instutite of Fluid Physics, CAEP, Mianyang (China)
Description
The process of emittance increase in proton radiography is analyzed. A radiographic system is designed, and based on it the factors affecting emittance increase are studied with theoretical analysis and Monte Carlo simulation. The results show that the extracted emittance from the accelerator is neglectable for high energy proton radiography, and cannot be neglected for medium energy proton radiography. The extracted emittance could be reduced through decreasing the thickness of the diffuser and enhancing the focusing ability of the accelerator's extraction system. (authors)
Additional details
Publishing Information
- Journal Title
- High Power Laser and Particle Beams
- Journal Volume
- 25
- Journal Issue
- 3
- Journal Page Range
- p. 778-782
- ISSN
- 1001-4322
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 47083710
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- ACCELERATORS; BEAM EMITTANCE; BEAM EXTRACTION; COMPUTERIZED SIMULATION; DESIGN; DIFFUSERS; FOCUSING; MONTE CARLO METHOD; PROTON RADIOGRAPHY; THICKNESS
- Descriptors DEC
- CALCULATION METHODS; DIMENSIONS; INDUSTRIAL RADIOGRAPHY; MATERIALS TESTING; NONDESTRUCTIVE TESTING; SIMULATION; TESTING
Optional Information
- Notes
- 3 figs., 8 refs.