Published February 5, 2002 | Version v1
Journal article

First results from Position-Sensitive quantum calorimeters using Mo/Au Transition-Edge Sensors

  • 1. NASA Goddard Space Flight Center, Greenbelt, Maryland 20771 (United States)

Description

We report the first results from a high-energy-resolution imaging spectrometer called a Position-Sensitive Transition-Edge Sensor (PoST). A PoST is a quantum calorimeter consisting of two Transition Edge Sensors (TESs) on the ends of a long absorber to do one dimensional imaging spectroscopy. Comparing rise time and energy information, the position of the event in the PoST is determined. Energy is inferred from the sum of the two pulses. We have fabricated 7- and 15-pixel PoSTs using Mo-Au TESs and Au absorbers. We have achieved 32 eV FWHM energy resolution at 1.5 keV with a 7-pixel PoST calorimeter

Additional details

Identifiers

Publishing Information

Journal Title
AIP Conference Proceedings
Journal Volume
605
Journal Issue
1
Journal Page Range
p. 239-242
ISSN
0094-243X
CODEN
APCPCS

Conference

Title
9. international workshop on low temperature detectors
Dates
22-27 Jul 2001
Place
Madison, WI (United States)

Optional Information

Notes
(c) 2002 American Institute of Physics.