Published October 1979
| Version v1
Journal article
Determination of time constants of reactor pressure and temperature sensors: the dynamic data system method
Description
A new modeling technique is introduced for on-line sensor time constant identification, both for the resistance temperature detector (RTD) and for the pressure sensor using power plant operational data. The sensor's time constant is estimated from a real characteristic root of the fitted autoregressive moving average model. The RTD's time constant values were identified to be 8.4 s, with a standard deviation of 1.2 s. The pressure sensor time constant was identified to be 28.6 ms, with a standard deviation of 3.5 ms
Additional details
Publishing Information
- Journal Title
- Nucl. Sci. Eng.
- Journal Volume
- 72
- Journal Issue
- 1
- Series
- Nucl. Sci. Eng.
- Journal Page Range
- 84-96
- ISSN
- 0029-5639
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 11538454
- Subject category
- S22: GENERAL STUDIES OF NUCLEAR REACTORS;
- Descriptors DEI
- MATHEMATICAL MODELS; ON-LINE SYSTEMS; PRESSURE GAGES; REACTOR COMPONENTS; SENSITIVITY; TEMPERATURE MONITORING; TIME DEPENDENCE
- Descriptors DEC
- MEASURING INSTRUMENTS; MONITORING