Automated double-cone-beam CT fusion technique. Enhanced evaluation of glue distribution in cases of spinal dural arteriovenous fistula (SDAVF) embolisation
- 1. Fondazione IRCCS Istituto Neurologico Carlo Besta, Department of Interventional Neuroradiology, Milan (Italy)
- 2. Foundation Neurological Institute ''C. Besta'', Department of Interventional Neuroradiology, Milan (Italy)
- 3. Foundation Neurological Institute ''C. Besta'', Department of Neuroimmunology and Neuromuscular Diseases, Milan (Italy)
- 4. Foundation Neurological Institute ''C. Besta'', Department of Neuro-Oncology, Milan (Italy)
- 5. Azienda Ospedaliera Universitaria Integrata Borgo Trento, Department of Neuroradiology, Verona (Italy)
Description
Spinal dural arteriovenous fistulas (SDAVFs) are acquired diseases that represent the majority of all arteriovenous spinal shunts, leading to progressive and disabling myelopathy. Treatment is focused on accurately disconnecting the fistula point. We present our experience with the double-cone-beam CT fusion technique successfully applied to evaluate treatment results in a series of SDAVFs. Between November 2011 and December 2015 we performed double-DynaCT acquisition (pre- and post-embolisation) in 12 cases of SDAVF. A successful DynaCT fusion technique was only achieved in the group of patients with pre- and post-treatment images acquired at the same time as the treatment session, under general anaesthesia (4/12). DynaCT performed on different days proved to be inadequate for the automated fusion technique because of changes in the body position (8/12). A pre-treatment flat-panel cone-beam CT with contrast, at the time of diagnostic angiography, can be very helpful to detect the correct level of the fistula and the relationship between the fistula and the surrounding structures. In case of the endovascular approach, additional post-treatment native acquisition merged with the pre-treatment acquisition (double-cone-beam CT fusion technique) permits to immediately evaluate the distribution of the glue cast and to confirm the success of the procedure. (orig.)
Availability note (English)
Available from: http://dx.doi.org/10.1007/s00330-016-4551-8Additional details
Identifiers
Publishing Information
- Journal Title
- European Radiology
- Journal Volume
- 27
- Journal Issue
- 5
- Journal Page Range
- p. 2200-2205
- ISSN
- 0938-7994
- CODEN
- EURAE3
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 48053434
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ANESTHESIA; AUTOMATION; BEAM PROFILES; COMPUTERIZED TOMOGRAPHY; CONTRAST MEDIA; EDEMA; EMBOLI; FISTULAE; IMAGE PROCESSING; NMR IMAGING; RADIATION DOSES; RELAXATION TIME; SPATIAL RESOLUTION; SPINAL CORD; THERAPY; VASCULAR DISEASES; WEIGHTING FUNCTIONS
- Descriptors DEC
- CARDIOVASCULAR DISEASES; CENTRAL NERVOUS SYSTEM; DIAGNOSTIC TECHNIQUES; DISEASES; DOSES; FUNCTIONS; MEDICINE; NERVOUS SYSTEM; PATHOLOGICAL CHANGES; PROCESSING; RESOLUTION; SYMPTOMS; TOMOGRAPHY