Published 1993
| Version v1
Report
Open
A medical proton synchrotron
- 1. Joint Inst. for Nuclear Research, Dubna (Russian Federation)
- 2. Ceskoslovenska Akademie Ved, Prague (Czech Republic). Fyzikalni Ustav
Description
A special medical weak-focusing synchrotron using only wedge focusing at dipole ends, is proposed to make a proton cancer therapy. A new method of the turn number calculation in a proton synchrotron allowing to calculate the energy gain per turn, is formulated. 13 refs.; 10 figs.; 1 tab
Availability note (English)
MF available from INIS under the Report Number.Files
25000712.pdf
Files
(201.5 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:a604101d955753d89f0d958671a79665
|
201.5 kB | Preview Download |
System files
(20.6 kB)
| Name | Size | Download all |
|---|
Additional details
Additional titles
- Original title (Russian)
- Медицинский протонный синхротрон
Publishing Information
- Imprint Pagination
- 14 p.
- Report number
- JINR--9-93-59
INIS
- Country of Publication
- Russian Federation
- Country of Input or Organization
- Russian Federation
- INIS RN
- 25000712
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE; S43: PARTICLE ACCELERATORS;
- Descriptors DEI
- BEAM INJECTION; DEPTH DOSE DISTRIBUTIONS; ION SOURCES; MAGNETIC FIELDS; MEV RANGE 100-1000; PROTON BEAMS; RADIOTHERAPY; SYNCHROTRONS
- Descriptors DEC
- ACCELERATORS; BEAMS; CYCLIC ACCELERATORS; DISTRIBUTION; ENERGY RANGE; MEDICINE; MEV RANGE; NUCLEON BEAMS; PARTICLE BEAMS; RADIATION DOSE DISTRIBUTIONS; SPATIAL DISTRIBUTION; SPATIAL DOSE DISTRIBUTIONS; THERAPY