Published September 1986
| Version v1
Journal article
Mod increases AGR boiler output
Creators
- 1. Central Electricity Generating Board, Southampton (UK). Marchwood Engineering Labs.
- 2. Central Electricity Generating Board, Barnwood (UK). Generation Development and Construction Div.
Description
During the commissioning runs of the first reactor units at Heysham I and Hartlepool Advanced Gas-cooled Reactors (AGRs), non-uniform temperature distributions were observed across individual boiler units which were more severe than those predicted from the design analysis. This article describes the re-orificing (referruling) of the boilers to overcome this problem. The referruling has reduced boiler sensitivity and resulted in an increase of load of 7 or 8%. (U.K.)
Additional details
Publishing Information
- Journal Title
- Chart. Mech. Eng.
- Journal Volume
- 33
- Journal Issue
- 9
- Series
- Chart. Mech. Eng.
- Journal Page Range
- 58-62
- ISSN
- 0009-191X
- CODEN
- CHMGA
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- United Kingdom
- INIS RN
- 18019700
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- BOILERS; EFFICIENCY; HARTLEPOOL REACTOR; HEYSHAM-A REACTOR; HEYSHAM-B REACTOR; ORIFICES; POWER GENERATION; SENSITIVITY; TEMPERATURE DISTRIBUTION
- Descriptors DEC
- AGR TYPE REACTORS; CARBON DIOXIDE COOLED REACTORS; ENRICHED URANIUM REACTORS; GAS COOLED REACTORS; GRAPHITE MODERATED REACTORS; OPENINGS; POWER REACTORS; REACTORS; THERMAL REACTORS