Liver fibrosis staging using T1 mapping on gadoxetic acid-enhanced MRI compared with DW imaging
Creators
Description
Aim: To evaluate the utility of T1 mapping on gadoxetic acid-enhanced magnetic resonance imaging (MRI) and diffusion-weighted imaging (DWI) for staging liver fibrosis. Materials and methods: This retrospective study was approved by the institutional review board and included 145 patients (mean age: 54 years old; 115 men and 30 women). Necro-inflammatory activity grade (G) and liver fibrosis stage (S) were histopathologically determined. T1 relaxation time and apparent diffusion coefficient (ADC) of the liver were measured and the reduction rate of the T1 relaxation time (Δ%) was calculated. T1 relaxation time measurements were compared with ADC values according to S/G scores. Results: Unenhanced hepatobiliary phase (HBP) and Δ% of T1 relaxation times showed significant correlations with S/G scores (rho: 0.28, 0.51, −0.35 for the S score, 0.26, 0.39, −0.26 for the G score, respectively, p<0.05). ADC values showed significant correlation with the S score (rho: −0.17, p=0.04) and did not correlate significantly with the G score (rho: −0.07, p=0.39). The areas under receiver operator characteristics (AUC) curve of unenhanced HBP, Δ% T1 relaxation time, and the ADC value were 0.68, 0.82, 0.71, 0.61 for the identification of S≥3, and 0.63, 0.68, 0.62, 0.52 for the identification of G≥3, respectively. The HBP T1 relaxation time was better than that of ADC for identification of S≥3 (p=0.0005) and G≥3 (p=0.014). Conclusions: The HBP T1 relaxation time measurement on gadoxetic acid-enhanced MRI images might be a potential biomarker in the staging of hepatic fibrosis, and was more accurate than the ADC measurement. -- Highlights: •We compared the results of T1 relaxation time measurement with DWI-ADC measurement on evaluating the liver fibrosis stages(S)/necroinflammatory activity grade(G) scores. •T1 relaxation time measurements on Gadoxetic acid-enhanced MR imaging might be a potential biomarker in staging of hepatic fibrosis. •T1 relaxation time measurements on Gadoxetic acid-enhanced MR imaging were more accuracy than ADC measurement
Availability note (English)
Available from http://dx.doi.org/10.1016/j.crad.2015.04.014Additional details
Identifiers
- DOI
- 10.1016/j.crad.2015.04.014;
- PII
- S0009-9260(15)00159-2;
Publishing Information
- Journal Title
- Clinical Radiology
- Journal Volume
- 70
- Journal Issue
- 10
- Journal Page Range
- p. 1096-1103
- ISSN
- 0009-9260
- CODEN
- CLRAAG
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 47025620
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ACCURACY; BIOLOGICAL MARKERS; BIOMEDICAL RADIOGRAPHY; COMPARATIVE EVALUATIONS; DIFFUSION; FIBROSIS; IMAGES; INFLAMMATION; LIVER; MEN; NMR IMAGING; RELAXATION TIME; REVIEWS; WEIGHT; WOMEN
- Descriptors DEC
- ANIMALS; BODY; DIAGNOSTIC TECHNIQUES; DIGESTIVE SYSTEM; DOCUMENT TYPES; EVALUATION; FEMALES; GLANDS; MALES; MAMMALS; MAN; MEDICINE; NUCLEAR MEDICINE; ORGANS; PATHOLOGICAL CHANGES; PRIMATES; RADIOLOGY; SYMPTOMS; VERTEBRATES
Optional Information
- Copyright
- Copyright (c) 2015 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.