Published December 2016 | Version v1
Journal article

Wide-range structurally optimized channel for monitoring the certified power of small-core reactors

  • 1. Russian Federal Nuclear Center—All-Russian Scientific Research Institute of Experimental Physics (Russian Federation)

Description

The results of tests of a prototype version of a channel for monitoring the certified power of small-core reactors performed at the BR-K1 reactor at the All-Russian Scientific Research Institute of Experimental Physics are reported. An SNM-11 counter and commercial KNK-4 and KNK-3 compensated ion chambers were used as neutron detectors in the tested channel, and certified NCMM and CCMM measurement modules controlled by a PC with specialized software were used as measuring instruments. The specifics of metrological assurance of calibration of the channel in the framework of reactor power monitoring are discussed.

Additional details

Identifiers

Publishing Information

Journal Title
Physics of Atomic Nuclei
Journal Volume
79
Journal Issue
8
Journal Page Range
p. 1349-1356
ISSN
1063-7788
CODEN
PANUEO

INIS

Country of Publication
United States
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
48059063
Subject category
S22: GENERAL STUDIES OF NUCLEAR REACTORS;
Descriptors DEI
CALIBRATION; COMPUTER CODES; IONIZATION CHAMBERS; MONITORING; NEUTRON DETECTORS; POWER DENSITY; REACTOR CORES
Descriptors DEC
MEASURING INSTRUMENTS; RADIATION DETECTORS; REACTOR COMPONENTS

Optional Information

Copyright