Published 2018 | Version v1
Miscellaneous

Preliminary study of the portable Optically Stimulated Luminescence dosimetry system for measuring radiation doses more than 100 Gy

  • 1. Nagase-Landauer, Ltd., Tsukuba, Ibaraki (Japan)
  • 2. Graduate University for Advanced Studies (SOKENDAI), Hayama, Kanagawa (Japan)

Description

In the high intensity accelerators of the Japan Proton Accelerator Research Complex (J-PARC), a small size dosimeter for measuring radiation dose of more than 100 Gy is required. We studied the applicability of a commercialized Optically Stimulated Luminescence (OSL) dosimetry system using Al2O3:C crystals for radiation detection. To evaluate the dose response characteristics of the OSL dosimeter, the dosimeters were exposed to 0.09 - 696 Gy of 60Co gamma-rays and read using a portable OSL reader. A fitting curve for interpolating the experimental results was in good agreement with the response of dosimeters at ±3%. Based on the results, we concluded that our dosimetry system can evaluate the radiation dose of up to 245 Gy of 60Co gamma-rays. (author)

Part of:
Proceedings of the 15th annual meeting of Particle Accelerator Society of Japan

Additional details

Additional titles

Original title (English)
#7B2C#15#56DE##65E5##672C##52A0##901F##5668##5B66##4F1A##5E74##4F1A#

Publishing Information

Imprint Title
Proceedings of the 15th annual meeting of Particle Accelerator Society of Japan
Imprint Pagination
[1380 p.]
Journal Page Range
p. 1256-1259

Conference

Title
15. annual meeting of Particle Accelerator Society of Japan
Acronym
PASJ2018
Dates
7-10 Aug 2018
Place
Nagaoka, Niigata (Japan)

Optional Information

Notes
13 refs., 3 figs., 1 tab. Imprint:#7B2C#15#56DE##65E5##672C##52A0##901F##5668##5B66##4F1A##5E74##4F1A#