Published 1983 | Version v1
Report Open

Operation of the irradiation facilities

Description

In 1982, 48 companies utilized the 100kCi Co-60 irradiation facility for sterization of their medical products and food products such as gauze sponges, absorbent cotton, ginseng powder and etc. A total of 12,411 cartons of 44 different items of medical products and foods were irradiated for radiosterilization and total operation time was 5,582.3 hours. Source activity of radiosterilization facility was strengthened by supplementing 52,766 Ci Co-60 source. Radiation dosimetry for stationary and dynamic condition in the irradiation cell was done and dose distribution in irradited box was measured after supplement of Co-60 source. Ceric sulfate dosimeter system was used for routine dosimetry in order to guarentee the radiation dose and radiation dosimetry was performed 568 times. In order to develop suitable plastic material for radiosterilization, experiments on the protective effect of hydrocarbon oil on the oxidative degradation of polypropylene were performed. The pre-sterilization counting of contaminated microorganism was carried out on the 6 medical product and the sterility of the irradiated medical product was confirmed accoring to the K.P. IV and U.S.P. XX. (Author)

Availability note (English)

MF available from INIS under the Report Number.

Files

14796089.pdf

Files (1.7 MB)

Name Size Download all
md5:b795c9b13f76b138c12f6572f4579cc2
1.7 MB Preview Download

Additional details

Publishing Information

Imprint Pagination
57 p.
Report number
KAERI/MR--35/82