Published 2024 | Version v1
Journal article

Assessing peri-implant bone microarchitecture - conventional vs. osseodensification drilling: ex vivo analysis

  • 1. Universidade Federal de Juiz de Fora (UFJF), Juiz de Fora, MG (Brazil)
  • 2. Universidade Federal do Rio de Janeiro (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil)

Description

The aim was to evaluate primary implant stability and bone microarchitecture in two drilling situations, by comparing the conventional technique (CT) and osseodensification (OD) (Versah Burs - Jackson - Mississippi - USA). The implant insertion torque (IT), implant stability quotient (ISQ), and the peri-implant trabecular microstructure were assessed on bone fragments obtained from pig's tibia (n=12), divided between CT (n=6) and OD (n=6). After the drilling procedure, the implants were installed (3.5x8.5 mm, Epikut - SIN - São Paulo - Brazil). The IT and ISQ were measured using a digital torque wrench and resonance frequency analysis. Then, the bone fragments containing the implants were removed with a trephine and analyzed by Microtomography (μCT, 8.0 (μm). The comparison between groups was performed using the unpaired t-test (α=0.05). The results revealed that OD promotes a higher insertion torque (CT: 7.67±2.44 Ncm; OD: 19.78±5.26 Ncm) (p=0.0005), although ISQ was not different (CT: 61.33±4.66; OD: 63.25±4.58) (p=0.48). There was a significant increase in peri-implant bone volume (CT: 23.17±3.39 mm3 ; OD: 32.01±5.75 mm3 ) (p=0.008), and trabecular parameters: separation (CT: 0.4357±0.03 mm; OD: 0.3865±0.04 mm) (p=0.0449), number (CT: 1.626±0.18 1/mm; OD: 1.946±0.13 1/mm) (p=0.007), and thickness (CT: 0.1130±0.009 mm; OD: 0.1328±0.015 mm) (p=0.02). Structure model index (SMI) data demonstrate no significant differences between groups (CT: 1.7±0.2; OD: 1.4±0.4) (p=0.12). In conclusion, OD increases the insertion torque values and promotes beneficial changes regarding bone microarchitecture compared with CT, revealing more peri-implant bone volume with consequent higher primary stability. (author)

Additional details

Publishing Information

Journal Title
Brazilian Dental Journal (Online)
Journal Volume
35
Journal Page Range
9 p.
ISSN
1806-4760

INIS

Country of Publication
Brazil
Country of Input or Organization
Brazil
INIS RN
55101977
Subject category
S36: MATERIALS SCIENCE;
Descriptors DEI
BONE TISSUES; COMPUTERIZED TOMOGRAPHY; IMPLANTS; MICROSTRUCTURE; STABILITY; TEETH; TORQUE; VOLUME
Descriptors DEC
ANIMAL TISSUES; BODY; CONNECTIVE TISSUE; DIAGNOSTIC TECHNIQUES; DIGESTIVE SYSTEM; ORAL CAVITY; TOMOGRAPHY