Published February 1981
| Version v1
Journal article
Remotely controlled repair at Douglas Point
Creators
Description
The Douglas Point nuclear generating station, completed in 1966, was Canada's first venture in commercial nuclear power. The discovery, 11 years later, of two perforations in auxiliary piping in a high radiation area led Atomic Energy of Canada Ltd and Ontario Hydro to develop new approaches to remotely controlled repair that will have much wider applications. Eddy current and ultrasonic testing were used to determine the pattern and extent of wear in a pipe encircled by a U-bolt, without first removing the U-bolt. Progress was monitored using remote TV cameras. Welding tools were designed and fabricated for the repairs, and a manipulator was also designed to transport the tool into its place of work. (author)
Additional details
Publishing Information
- Journal Title
- Nucl. Eng. Int.
- Journal Volume
- 26
- Journal Issue
- 309
- Series
- Nucl. Eng. Int.
- Journal Page Range
- 35-42
- ISSN
- 0029-5507
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- United Kingdom
- INIS RN
- 12614080
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- DOUGLAS POINT ONTARIO REACTOR; EDDY CURRENT TESTING; IN-SERVICE INSPECTION; MANIPULATORS; NUCLEAR POWER PLANTS; PIPES; REACTOR MAINTENANCE; REPAIR; TUBES; ULTRASONIC TESTING; WEAR; WELDING; WELDING MACHINES
- Descriptors DEC
- ACOUSTIC TESTING; CANDU TYPE REACTORS; ELECTROMAGNETIC TESTING; FABRICATION; HEAVY WATER COOLED REACTORS; HEAVY WATER MODERATED REACTORS; INSPECTION; JOINING; LABORATORY EQUIPMENT; MAINTENANCE; MATERIALS TESTING; NATURAL URANIUM REACTORS; NONDESTRUCTIVE TESTING; NUCLEAR FACILITIES; PHWR TYPE REACTORS; POWER PLANTS; POWER REACTORS; PRESSURE TUBE REACTORS; REACTORS; REMOTE HANDLING EQUIPMENT; TESTING; THERMAL POWER PLANTS; THERMAL REACTORS