Effect of rod bow to partial closure on critical heat flux in PWR fuel assembly
Description
The effects of partial closure due to bowed rods on critical heat flux (CHF) in a pressurized water reactor rod bundle were evaluated by conducting tests in an electrically heated test section. The test section consisted of a 5x5 square rod array with 24 heated rods of 9.14 mm (0.360 in) diameter, each with a heated length of 3.66 m (12 ft) with Exxon Nuclear Company spacer grids on a 0.521 m (20.5 in) pitch. The central rod was a 12.2 mm (0.480 in) diameter unheated guide tube. The gap between two centrally located high powered rods was reduced 71% from nominal. The bow was approximately mid-span between two grids in the region in which CHF was observed in unbowed test sections. The results of these tests indicate a reduction in CHF of approximately 5% at 2400 psia and no reduction at 2000 psia when test repeatability is taken into consideration. The reduction in CHF at 2400 psia is substantially smaller than that inferred by linear interpolation of previously reported test results at 50 and 100% reduction of spacing. The local nature of CHF reduction due to rod bow was confirmed
Additional details
Publishing Information
- Journal Title
- Am. Soc. Mech. Eng., [Pap.]
- Journal Volume
- 83-HT-105
- Series
- Am. Soc. Mech. Eng., [Pap.].
- Journal Page Range
- 5
- ISSN
- 0402-1215
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 16003129
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Resource subtype / Literary indicator
- Numerical Data
- Descriptors DEI
- CRITICAL HEAT FLUX; DEFORMATION; EXPERIMENTAL DATA; FUEL RODS; PERFORMANCE TESTING; PRESSURE DEPENDENCE; PWR TYPE REACTORS; REACTOR SAFETY
- Descriptors DEC
- DATA; ENRICHED URANIUM REACTORS; FUEL ELEMENTS; HEAT FLUX; INFORMATION; NUMERICAL DATA; POWER REACTORS; REACTOR COMPONENTS; REACTORS; SAFETY; TESTING; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS