Measurement of implosion target parameters by X-ray phase contrast imaging

  • 1. Research Center of Laser Fusion, CAEP, Mianyang (China)
  • 2. Research Institute of Precision Engineering, Harbin Institute of Technology (China)

Description

The feasibility of measuring the location of the plastic microsphere in the gold hohlraum target by using coaxial-of-focus X-ray phase contrast imaging was theoretically analyzed, based on which an experiment was carried out. The experimental results show that, due to the phase modulation of low Z and low-density materials to high energy X-ray, a certain image contrast could be formed. This effect is independent on X-ray energy, so in a certain range of sizes, simultaneous imaging of high Z high-density and low Z low-density materials in the high-energy X-ray is achieved, which overcomes the shortcomings of traditional absorption imaging. The precision assembly parameters measurement of implosion target is realized. (authors)

Additional details

Publishing Information

Journal Title
High Power Laser and Particle Beams
Journal Volume
24
Journal Issue
11
Journal Page Range
p. 2627-2630
ISSN
1001-4322