Continuous fission-product monitor system at Oyster Creek. Final report
Description
A continuous on-line fission product monitor has been installed at the Oyster Creek Nuclear Generating Station, Forked River, New Jersey. The on-line monitor is a minicomputer-controlled high-resolution gamma-ray spectrometer system. An intrinsic Ge detector scans a collimated sample line of coolant from one of the plant's recirculation loops. The minicomputer is a Nuclear Data 6620 system. Data were accumulated for the period from April 1979 through January 1980, the end of cycle 8 for the Oyster Creek plant. Accumulated spectra, an average of three a day, were stored on magnetic disk and subsequently analyzed for fisson products, Because of difficulties in measuring absolute detector efficiency, quantitative fission product concentrations in the coolant could not be determined. Data for iodine fission products are reported as a function of time. The data indicate the existence of fuel defects in the Oyster Creek core during cycle 8
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS., PC A06/MF A01.
Files
Additional details
Publishing Information
- Imprint Pagination
- 125 p.
- Report number
- EPRI-NP--1577
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 12588896
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- FAILED ELEMENT MONITORS; FISSION PRODUCTS; GAMMA SPECTROMETERS; GE SEMICONDUCTOR DETECTORS; IODINE ISOTOPES; ON-LINE MEASUREMENT SYSTEMS; OYSTER CREEK-1 REACTOR; TIME DEPENDENCE
- Descriptors DEC
- BWR TYPE REACTORS; ENRICHED URANIUM REACTORS; ISOTOPES; MEASURING INSTRUMENTS; ON-LINE SYSTEMS; POWER REACTORS; RADIATION DETECTORS; RADIOACTIVE MATERIALS; REACTORS; SEMICONDUCTOR DETECTORS; SPECTROMETERS; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS