Published 1991 | Version v1
Report

Active neutron counting software for nuclear material verification with the neutron collar and the active well coincidence counter

  • 1. International Atomic Energy Agency, Vienna (Austria)
  • 2. Los Alamos National Lab., NM (United States)

Description

The Uranium Neutron Coincidence Collar (UNCL) is used by the International Atomic Energy Agency (IAEA) to verify the Uranium 235 and Uranium 238 content in Light Water Reactor (LWR) fuel assemblies. The IAEA uses also Active Neutron Coincidence Counter (AWCC) for the verification of the Uranium 235 content in uranium samples and MTR fuel assemblies. This paper describes the Active Neutron Counting System (ANCS). The application software is considered to be user-friendly and can lead inspectors through the measurement steps and provide final evaluation in the field and at the IAEA. The software is based on the functional specification prepared by the IAEA and reviewed by the Los Alamos National Laboratory. The algorithms were provided by the IAEA in consultation with LANL

Part of:
Safeguards and Nuclear Material Management

Additional details

Publishing Information

Imprint Title
Safeguards and nuclear material management
Imprint Pagination
745 p.
Journal Page Range
p. 473-475.
Report number
EUR--13686

Conference

Title
13. Annual Symposium on Safeguards and Nuclear Material Management.
Dates
14-16 May 1991.
Place
Avignon (France).

Optional Information