Published 1980 | Version v1
Report Open

Modelling of pool fire environments using experimental results of a two-hour test of a railcar/cask system

Description

It was demonstrated that time and spatial variations in the local source temperatures, the radiant shielding of intervening structure and the effects of wind can significantly affect the amount of heat input to a large package in a simulated accidental fire. The pool fire provided a significantly non-uniform heat source to the package. Despite these effects, however, the amount of heat input to the package was generally equivalent to that which would be received from a regulatory 8000C uniform thermal source. 7 firegures

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS., PC A02/MF A01.

Files

12585547.pdf

Files (273.9 kB)

Name Size Download all
md5:bcf089481523e8ab06ce745213570b55
273.9 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
8 p.
Report number
SAND--80-0906C

Conference

Title
6. international symposium on packaging and transporting radioactive material.
Dates
10 Nov 1980.
Place
Berlin, F.R. Germany.

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
12585547
Subject category
S42: ENGINEERING;
Resource subtype / Literary indicator
Conference
Descriptors DEI
CASKS; FIRES; FLAMES; FORCED CONVECTION; RESPONSE FUNCTIONS; SIMULATION; SPATIAL DISTRIBUTION; TIME DEPENDENCE; VEHICLES
Descriptors DEC
CONTAINERS; CONVECTION; DISTRIBUTION; ENERGY TRANSFER; FUNCTIONS; HEAT TRANSFER

Optional Information

Secondary number(s)
CONF-801115--12.