Tumor-dose-rate variations during robotic radiosurgery of oligo and multiple brain metastases
Creators
- 1. Saphir Radiosurgery Center Frankfurt and Northern Germany, Guestrow (Germany)
- 2. Department of Radiation Oncology, University Medicine Rostock, Rostock (Germany)
- 3. Strahlenklinik, University Hospital Essen, Hufelandstr. 55, Essen (Germany)
- 4. Department of Radiation Oncology, Karl-Lennert-Krebscentrum Nord, University Medical Center Schleswig-Holstein, Campus Kiel, Arnold-Heller-Straße 3, Haus 50, 24105, Kiel (Germany)
- 5. Institute for Robotics and Cognitive Systems, University of Luebeck, Luebeck (Germany)
- 6. Department of Radiation Oncology, University Medical Center Schleswig-Holstein, Luebeck (Germany)
- 7. Department of Radiation Oncology, University Medicine Greifswald, Greifswald (Germany)
- 8. Department of Neurosurgery, University Hospital Frankfurt, Frankfurt (Germany)
Description
For step-and-shoot robotic stereotactic radiosurgery (SRS) the dose delivered over time, called local tumor-dose-rate (TDR), may strongly vary during treatment of multiple lesions. The authors sought to evaluate technical parameters influencing TDR and correlate TDR to clinical outcome. A total of 23 patients with 162 oligo (1-3) and multiple (>3) brain metastases (OBM/MBM) treated in 33 SRS sessions were retrospectively analyzed. Median PTV were 0.11 cc (0.01-6.36 cc) and 0.50 cc (0.12-3.68 cc) for OBM and MBM, respectively. Prescription dose ranged from 16 to 20 Gy prescribed to the median 70% isodose line. The maximum dose-rate for planning target volume (PTV) percentage p in time span s during treatment (TDR) was calculated for various p and s based on treatment log files and in-house software. TDR was 0.30 Gy/min (0.23-0.87 Gy/min) for OBM and 0.22 Gy/min (0.12-0.63 Gy/min) for MBM, respectively, and increased by 0.03 Gy/min per prescribed Gy. TDR strongly correlated with treatment time (ρ = -0.717, p < 0.001), monitor units (MU) (ρ = -0.767, p < 0.001), number of beams (ρ = -0.755, p < 0.001) and beam directions (ρ = -0.685, p < 0.001) as well as lesions treated per collimator (ρ = -0.708, P < 0.001). Median overall survival (OS) was 20 months and 1- and 2-year local control (LC) was 98.8% and 90.3%, respectively. LC did not correlate with any TDR, but tumor response (partial response [PR] or complete response [CR]) correlated with all TDR in univariate analysis (e.g., TDR: hazard ration [HR] = 0.974, confidence interval [CI] = 0.952-0.996, p = 0.019). In multivariate analysis only concomitant targeted therapy or immunotherapy and breast cancer tumor histology remained a significant factor for tumor response. Local grade ≥2 radiation-induced tissue reactions were noted in 26.3% (OBM) and 5.2% (MBM), respectively, mainly influenced by tumor volume (p < 0.001). Large TDR variations are noted during MBM-SRS which mainly arise from prolonged treatment times. Clinically, low TDR corresponded with decreased local tumor responses, although the main influencing factor was concomitant medication.
Additional details
Identifiers
Publishing Information
- Journal Title
- Strahlentherapie und Onkologie
- Journal Volume
- 197
- Journal Issue
- 7
- Journal Page Range
- p. 581-591
- ISSN
- 0179-7158
- CODEN
- STONE4
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 52098524
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- BRAIN; CARCINOMAS; COMPUTER CODES; DOSE RATES; DOSE-RESPONSE RELATIONSHIPS; EXTERNAL BEAM RADIATION THERAPY; GY RANGE 10-100; HISTOLOGY; IMAGE PROCESSING; IMMUNOTHERAPY; MAMMARY GLANDS; METASTASES; MULTIVARIATE ANALYSIS; RADIATION DOSES; RADIOBIOLOGY; ROBOTS; SURGERY; SURVIVAL CURVES
- Descriptors DEC
- ABSORBED DOSE RANGE; BIOLOGY; BODY; CENTRAL NERVOUS SYSTEM; DISEASES; DOSES; EQUIPMENT; GLANDS; GY RANGE; MATHEMATICS; MEDICINE; NEOPLASMS; NERVOUS SYSTEM; NUCLEAR MEDICINE; ORGANS; PROCESSING; RADIATION DOSE RANGES; RADIOLOGY; RADIOTHERAPY; STATISTICS; THERAPY