Development of A MEMS Based Manometric Catheter for Diagnosis of Functional Swallowing Disorders

  • 1. Centre for Advanced Manufacturing Research, University of South Australia, Adelaide (Australia)
  • 2. School of Electrical and Information Engineering, University of South Australia (Australia)
  • 3. Centre for Paediatric and Adolescent Gastroenterology, Women's and Children's Hospital, Adelaide (Australia)

Description

Silicon pressure sensors based on micro-electro-mechanical-systems (MEMS) technologies are gaining popularity for applications in bio-medical devices. In this study, a silicon piezo-resistive pressure sensor die is used in a feasibility study of developing a manometric catheter for functional swallowing disorders diagnosis. The function of a manometric catheter is to measure the peak and intrabolus pressures along the esophageal segment during the swallowing action. Previous manometric catheters used the water perfusion technique to measure the pressure changes. This type of catheter is reusable, large in size and the pressure reading is recorded by an external transducer. Current manometric catheters use a solid state pressure sensor on the catheter itself to measure the pressure changes. This type of catheter reduces the discomfort to the patient but it is reusable and is very expensive. We carried out several studies and experiments on the MEMS-based pressure sensor die, and the results show the MEMS-based pressure sensors have a good stability and a good linearity output response, together with the advantage of low excitation biasing voltage and extremely small size. The MEMS-based sensor is the best device to use in the new generation of manometric catheters. The concept of the new MEMS-based manometric catheter consists of a pressure sensing sensor, supporting ring, the catheter tube and a data connector. Laboratory testing shows that the new calibrated catheter is capable of measuring pressure in the range from 0 to 100mmHg and maintaining stable condition on the zero baseline setting when no pressure is applied. In-vivo tests are carried out to compare the new MEMS based catheter with the current version of catheters used in the hospital

Availability note (English)

Available online at http://stacks.iop.org/1742-6596/34/955/jpconf6_34_158.pdf or at the Web site for the Journal of Physics. Conference Series (Online) (ISSN 1742-6596) http://www.iop.org/

Additional details

Publishing Information

Journal Title
Journal of Physics. Conference Series (Online)
Journal Volume
34
Journal Issue
1
Journal Page Range
p. 955-960
ISSN
1742-6596

Conference

Title
International MEMS conference 2006
Acronym
iMEMS2006
Dates
9-12 May 2006
Place
Singapore (Singapore)

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
37058628
Subject category
S75: CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND SUPERFLUIDITY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
COMPARATIVE EVALUATIONS; CONNECTORS; DIAGNOSIS; ELECTRIC POTENTIAL; ELECTROMECHANICS; EXCITATION; FEASIBILITY STUDIES; IN VIVO; MICROSTRUCTURE; SILICON; STABILITY; TESTING; TRANSDUCERS; TUBES
Descriptors DEC
CONDUCTOR DEVICES; ELECTRICAL EQUIPMENT; ELEMENTS; ENERGY-LEVEL TRANSITIONS; EQUIPMENT; EVALUATION; MECHANICS; SEMIMETALS