Study on integrity evaluation of structures associated with nuclear power plants
Description
The 3.11 Tohoku District -off the Pacific Ocean Earthquake and tsunami made us observations of tsunami height in large exceedance of the design, and besides it gave the most damages to several nuclear power plants facing the Pacific Ocean at source area of the earthquake. Particularly, at Fukushima-Daiichi Nuclear Power Plant, the great tsunami caused the simultaneous failure on several plant's equipment and components, which escalated into the core damage. Considering these background, the objective of this research is to enhance fundamental technology relative to integrity evaluation of SSC's (System, Structure, components) targeting external events such as earthquakes and tsunamis. Specifically, it is performed to develop structure evaluation methods against tsunami, to develop seismic isolation system, and to enhance non-liner analysis methods for building and so on. In viewpoint of the other external events except earthquake and tsunami, it was performed to develop impact analysis methods on building and outdoor structure against swept things caused by tornadoes. After that on the basis of these developments, it is performed to draw up guidelines such as the base isolation structure review guide, and the structure design and risk evaluation guide against tsunami, which are to be used in cross-check analysis targeting integrity evaluation of nuclear power plant's structures against external events such as earthquakes and tsunamis. (author)
Additional details
Publishing Information
- Imprint Title
- Annual safety research report, JFY 2012
- Imprint Pagination
- 708 p.
- Journal Page Range
- p. 101-110
- Report number
- JNES-RE--2013-0001-Rev.1
INIS
- Country of Publication
- Japan
- Country of Input or Organization
- Japan
- INIS RN
- 51066965
- Subject category
- S22: GENERAL STUDIES OF NUCLEAR REACTORS;
- Resource subtype / Literary indicator
- Non-conventional Literature
- Descriptors DEI
- CONTAINMENT BUILDINGS; COOLING SYSTEMS; DESIGN; EARTHQUAKES; EXCEPTIONAL NATURAL DISASTER; FUKUSHIMA-1 REACTOR; FUKUSHIMA-2 REACTOR; FUKUSHIMA-3 REACTOR; FUKUSHIMA-4 REACTOR; MELTDOWN; NUCLEAR POWER PLANTS; PIPES; RECOMMENDATIONS; SAFETY ENGINEERING; TSUNAMIS
- Descriptors DEC
- ACCIDENTS; BEYOND-DESIGN-BASIS ACCIDENTS; BUILDINGS; BWR TYPE REACTORS; CONTAINMENT; ENERGY SYSTEMS; ENGINEERING; ENRICHED URANIUM REACTORS; GRAVITY WAVES; NATURAL DISASTERS; NUCLEAR FACILITIES; POWER PLANTS; POWER REACTORS; REACTOR ACCIDENTS; REACTORS; SEISMIC EVENTS; SEVERE ACCIDENTS; THERMAL POWER PLANTS; THERMAL REACTORS; TUBES; WATER COOLED REACTORS; WATER MODERATED REACTORS; WATER WAVES
Optional Information
- Notes
- 11 figs.; This record replaces 46066577; This record replaces 48062887