Published August 1972
| Version v1
Journal article
Overvoltage and breakdown patterns of fast Marx generators
Creators
Description
Spark gap overvoltages of fast Marx generators in the 100-300 kv range were studied as a function of stray and interstage capacitance for several circuit designs. Overvoltage measurements were made at low voltages by simulating the spark with a silicon-controlled rectifier. Breakdown times were measured to nanoseconds by viewing the light flash from the sparks with a fast photomultiplier. The influence of the ultraviolet irradiation on breakdown time was studied by masking the first gap. Practical conclusions for Marx generator design are presented.
Additional details
Identifiers
Publishing Information
- Journal Title
- IEEE Transactions on Nuclear Science
- Journal Volume
- 19
- Journal Issue
- 4
- Series
- IEEE (Inst. Elec. Electron. Eng.), Trans. Nucl. Sci.
- Journal Page Range
- 20-31
- ISSN
- 0018-9499
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 4065824
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; S43: PARTICLE ACCELERATORS;
- Descriptors DEI
- BREAKDOWN; HIGH-VOLTAGE PULSE GENERATORS
- Descriptors DEC
- ELECTRONIC EQUIPMENT; PULSE GENERATORS
Optional Information
- Notes
- Updated automatically by Metadata and Full-Text Enrichment Agent