Published February 1983 | Version v1
Journal article

A simple facility for the aseptic preparation of 111In-labelled leucocytes

  • 1. Kent and Canterbury Hospital (UK)

Description

The sterility of the procedure for labelling leucocytes with 111In oxine for diagnostic scanning purposes was assessed using a simple existing facility, i.e. an enclosed Perspex box. All manipulations of the blood were performed in the box via two open ports through which the operator's gloved hands and forearms were inserted. It was concluded that this simple facility, coupled with a strict aseptic technique, provided an acceptable standard of asepsis for the labelling of leucocytes with 111In oxine. (U.K.)

Additional details

Publishing Information

Journal Title
Nucl. Med. Commun.
Journal Volume
4
Journal Issue
1
Series
Nucl. Med. Commun.
Journal Page Range
24-30
ISSN