Initial investigation of factors influencing radiation dose to patients undergoing barium-based fluoroscopy procedures in Tanzania
- 1. Department of Physics, University of Dar es Salaam, P O Box 35063, Dar es Salaam (Tanzania, United Republic of)
- 2. Department of Radiology, Muhimbili University of Health and Allied Sciences, P O Box 65001, Dar es Salaam (Tanzania, United Republic of)
- 3. Departments of Oncology and Physics, Queens University, Kingston, ON, K7L 5P9 (Canada)
Description
The aim of this study was to investigate the nature and causes of radiation dose imparted to patients undergoing barium-based X-ray fluoroscopy procedures in Tanzania and to compare these doses to those reported in the literature from other regions worldwide. The air kerma area product (KAP) to patient undergoing barium investigations of gastrointestinal tract system was obtained from four consultant hospitals. The KAP was determined using a flat transparent transmission ionization chamber. Mean values of KAP for barium swallow (BS), barium meal (BM) and barium enema (BE) were 2.79, 2.62 and 15.04 Gy cm2, respectively. The mean values of KAP per hospital for the BS, BM and BE procedures varied by factors of up to 7.3, 1.6 and 2.0, respectively. The overall difference between individual patient doses across the four consultant hospitals investigated differed by factors of up to 53, 29.5 and 12 for the BS, BM and BE procedures, respectively. The majority of the mean values of KAP was lower than the reported values for Ghana, Greece, Spain and the UK, while slightly higher than those reported for India. The observed wide variation of KAP values for the same fluoroscopy procedure within and among the hospitals was largely attributed to the dynamic nature of the procedures, the patient characteristics, the skills and experience of personnel, and the different examination protocols employed among hospitals. The observed great variations of procedural protocols and patient doses within and across the hospitals call for the need to standardize examination protocols and optimize barium-based fluoroscopy procedures. (authors)
Availability note (English)
Available from doi: http://dx.doi.org/10.1093/rpd/ncw141Additional details
Identifiers
- DOI
- 10.1093/rpd/ncw141;
Publishing Information
- Journal Title
- Radiation Protection Dosimetry
- Journal Volume
- 174
- Journal Issue
- 2
- Journal Page Range
- p. 262-274
- ISSN
- 0144-8420
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- France
- INIS RN
- 48062198
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY; S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- BARIUM; FLUOROSCOPY; GASTROINTESTINAL TRACT; HOSPITALS; IONIZATION CHAMBERS; KERMA; PATIENTS; RADIATION DOSES; STANDARDIZATION; UNITED REPUBLIC OF TANZANIA
- Descriptors DEC
- AFRICA; ALKALINE EARTH METALS; BIOMEDICAL RADIOGRAPHY; BUILDINGS; DEVELOPING COUNTRIES; DIAGNOSTIC TECHNIQUES; DIGESTIVE SYSTEM; DOSES; ELEMENTS; MEASURING INSTRUMENTS; MEDICAL ESTABLISHMENTS; MEDICINE; METALS; NUCLEAR MEDICINE; RADIATION DETECTORS; RADIOLOGY
Optional Information
- Notes
- 31 refs.