Diagnostic accuracy of whole-body diffusion-weighted magnetic resonance imaging with 3.0 T in detection of primary and metastatic neoplasms
- 1. Department of Radiology, Gulhane Military Medical School, Ankara (Turkey)
- 2. Department of Nuclear Medicine, Gulhane Military Medical School, Ankara (Turkey)
Description
To discuss the accuracy of the whole-body diffusion-weighted imaging with background body signal suppression (WB-DWIBS) technique performed in the 3.0-T system. We studied 17 patients who underwent positron emission tomography (PET)/CT and WB-DWIBS examinations for staging their diseases. The DWIBS pulse and echo-planar imaging-short T1 inversion recovery single-shot pulse sequences were performed for WB-DWIBS. A PET/CT scan was performed with 18-fluorodeoxyglucose. The lesions were localised and counted in both of the examinations, and WB-DWIBS was evaluated for the neoplastic tissue detection rate, while PET/CT was accepted as the reference standard modality. The WB-DWIBS scan had a room occupation time of 32–35min. All of the metastasis positive patients (n=12) detected with PET/CT were also detected with WB-DWIBS (100%). In our patient group, there were a total of 109 bone metastases on PET/CT scans, and 93 of them (85.3%) were demonstrated with WB-DWIBS. We detected 128 metastatic lymph nodes on PET/CT, and 123 of them (96.3%) were demonstrated with WB-DWIBS. There were a total of 17 liver metastases on PET/CT, and 15 of them (88.2%) were detected with WB-DWIBS. There was no statistically significant difference between the two imaging modalities in detecting bone, lymph node and liver metastases (P>0.05). WB-DWIBS is a non-invasive technique that may successfully detect the spreading of the tumoural tissue in cancer patients when compared with PET/CT.
Availability note (English)
Available from http://dx.doi.org/10.1111/1754-9485.12026Additional details
Identifiers
Publishing Information
- Journal Title
- Journal of Medical Imaging and Radiation Oncology
- Journal Volume
- 57
- Journal Issue
- 3
- Journal Page Range
- p. 274-282
- ISSN
- 1754-9477
INIS
- Country of Publication
- Australia
- Country of Input or Organization
- Australia
- INIS RN
- 46013083
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ACCURACY; CAT SCANNING; CLINICAL TRIALS; DIAGNOSTIC TECHNIQUES; DIFFUSION; FLUORODEOXYGLUCOSE; METASTASES; NEOPLASMS; NMR IMAGING; POSITRON COMPUTED TOMOGRAPHY
- Descriptors DEC
- ANTIMETABOLITES; COMPUTERIZED TOMOGRAPHY; DIAGNOSTIC TECHNIQUES; DISEASES; DRUGS; EMISSION COMPUTED TOMOGRAPHY; TESTING; TOMOGRAPHY
Optional Information
- Notes
- 4 figs., 2 tabs.