Published August 2016 | Version v1
Journal article

Research on flashing high counting rate of ex-core neutron instrumentation system of nuclear power plant

  • 1. Nuclear and Radiation Safety Center MEP, Beijing (China)

Description

Several anomalies of flashing high counting rate in ex-core neutron instrumentation system occurred recently in some new nuclear power plants in China. As reasons of these anomalies, the cable connector problems and detector failure problems are analyzed from aspects of fault phenomenon, cause examination, and solutions. Concerns on the manufacture and installation of ex-core neutron instrumentation equipment should be raised by nuclear power plants. This paper can be used for reference on solution and avoiding similar issues for other nuclear power plants. (authors)

Additional details

Publishing Information

Journal Title
Nuclear Electronics and Detection Technology
Journal Volume
36
Journal Issue
8
Journal Page Range
p. 852-855
ISSN
0258-0934

Optional Information

Notes
2 figs., 2 tabs., 1 ref.