Published February 13, 2013 | Version v1
Report Open

Large Cryogenic Germanium Detector. Final Report

Description

The goal of this project was to investigate possible ways of increasing the size of cryogenic Ge detectors. This project identified two possible approaches to increasing the individual cryogenic Ge detector size. The first approach relies on using the existing technology for growing detector-grade (high-purity) germanium crystals of dislocation density 100-7000 cm-2. The second approach is to consider dislocation-free Ge crystals

Files

45031576.pdf

Files (26.5 kB)

Name Size Download all
md5:992784f967cd68f22ab41603e329f259
26.5 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
3 p.
Report number
DOE-SC--0002394-1-Final

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
45031576
Subject category
S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
Descriptors DEI
CRYSTALS; DISLOCATIONS; GE SEMICONDUCTOR DETECTORS; GERMANIUM
Descriptors DEC
CRYSTAL DEFECTS; CRYSTAL STRUCTURE; ELEMENTS; LINE DEFECTS; MEASURING INSTRUMENTS; METALS; RADIATION DETECTORS; SEMICONDUCTOR DETECTORS

Optional Information

Contract/Grant/Project number
SC0002394
Funding organization
USDOE Office of Science - SC (United States)
Secondary number(s)
OSTIID--1062741