Technical improvement for the output drive unit of the reactor protection system in QNPP

  • 1. Qinshan Nuclear Power Company, Haiyan, ZJ (China)

Description

For improving the reliability of the output drive unit of the reactor protection system in Qinshan NPP, the former design of this part was improved and researched on the problem appeared during the commissioning and operation under the conditions of narrow process space of cabinets and unchanged overall arrangement: (1) The output relay modules was redesigned to unify the relay specification to improve the versatility, and also to improve the pin's contact by means of welding them directly on the printed circuit boards and to make the modules detachable by connectors instead of previously non-detachable. Th modules were connected in series by both power supply line and ground line which were finally connected at same point respectively, so that other protection signals can still be output correctly when a single module is removed. (2) The relay drive circuit was also redesigned for working in on-off state instead of in amplification to minimize the power consumption. On the other hand, the CMOS buffers were taken to couple the CMOS circuits to the TTL circuits. The actuating time for the new shutdown relay was decreased from the former 35 ms to 5 ms, the actuating time for the engineered safety feature drive signal relay was decreased from 10 ms to 6 ms after the above-mentioned improvements, the reliability of the RPS is remarkably improved and a great economic benefit is obtained. (4 refs., 3 figs., 2 tabs.)

Availability note (English)

MF available from INIS under the Report Number.

Files

27026152.pdf

Files (379.4 kB)

Name Size Download all
md5:6d7ab9c17062c166698d83c246df0f74
379.4 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
8 p.
Report number
CNIC--00991

Optional Information

Secondary number(s)
QNPC--0006.