Published July 1982
| Version v1
Report
Restricted
CSQ calculations of H2 detonations in the Zion and Sequoyah nuclear plants
Description
This report presents results from eleven calculations concerning the detonation of a dry hydrogen:air mixture in various models of nuclear reactor containment structures. One calculation treats a large, dry containment (Zion); the remaining analyses consider separate portions of an ice condenser containment (Sequoyah). The calculations were carried out with a well-tested, two-dimensional continuum mechanics code, using a simplified model that forces detonation to occur. All problem boundaries were treated as rigid - that is, no attempt was made to characterize the response of the structures to the loads imposed on them
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS, PC A04/MF A01 - GPO as DE82021178.
Files
Additional details
Publishing Information
- Imprint Pagination
- 52 p.
- Report number
- NUREG/CR--2385
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 14787201
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY; S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- COMPUTER CALCULATIONS; CONTAINMENT BUILDINGS; EXPLOSIONS; HYDROGEN; REACTOR ACCIDENTS; REACTOR SAFETY; SEQUOYAH-1 REACTOR; SEQUOYAH-2 REACTOR; TWO-DIMENSIONAL CALCULATIONS; ZION-1 REACTOR; ZION-2 REACTOR
- Descriptors DEC
- ACCIDENTS; CONTAINMENT; ELEMENTS; ENRICHED URANIUM REACTORS; NONMETALS; POWER REACTORS; PWR TYPE REACTORS; REACTORS; SAFETY; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS
Optional Information
- Secondary number(s)
- SAND--81-2216.