Published June 1993 | Version v1
Journal article

Vacuum-extractive determination of oxygen and carbon in pure indium, gallium and tin

Description

Trace amounts of oxygen and carbon at the level 0.1-0.5 mass pmm in indium, gallium, and tin were determined by a vacuum-extractive method. The process of carbon extraction had the first order of concentration and was completed in 30-90 s. The limit of detection for oxygen and carbon, evaluated by the double deviation of blank values, was 1-3x10-6%. These values are limited by surface contamination of the sample. The relative standard deviation was 0.1-0.15 for the content range 10-4-10-5%. Accuracy of the results of analysis was shown by comparison with the data of MG-activation and gamma-activation methods

Additional details

Additional titles

Original title (Russian)
Вакуум-экстракционное определение кислорода и углерода в чистых индии, галии и олове

Publishing Information

Journal Title
Vysokochistye Veshchestva
Journal Issue
no.6
Journal Page Range
p. 100-113.
ISSN
0235-0122
CODEN
VYVEEC

INIS

Country of Publication
Russian Federation
Country of Input or Organization
Russian Federation
INIS RN
26014193
Subject category
S37: INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL CHEMISTRY;
Descriptors DEI
ACCURACY; ACTIVATION ANALYSIS; CARBON; GASES; INDIUM; OXYGEN; PURIFICATION; QUANTITATIVE CHEMICAL ANALYSIS; SENSITIVITY; SEPARATION PROCESSES; SURFACES; TRACE AMOUNTS
Descriptors DEC
CHEMICAL ANALYSIS; ELEMENTS; FLUIDS; METALS; NONDESTRUCTIVE ANALYSIS; NONMETALS