Method for determining hydrogen concentration in liquid sodium coolant circuit of nuclear reactor utilizing the semiconductor sensors

Description

A method for determining hydrogen content in the second ircuit of a fast reactor by means of gas semiconductor sensors on the base of MDS structure is presented. The system is tested in a laboratory sodium circuit in the hydrogen concentration range in sodium of 0.02-100 mln-1. By means of the system was detected with confidence the variation of the hydrogen concentration in sodium of 0.01 mln-01 (mass) during approximately 30s

Additional details

Additional titles

Original title (Russian)
Определение содержания водорода в натриевом контуре быстрого реактора с помощью полупроводниковых сенсоров

Publishing Information

Journal Title
Atomnaya Ehnergiya
Journal Volume
73
Journal Issue
5
Journal Page Range
p. 370-374.
ISSN
0004-7163
CODEN
AENGAB