Reproducibility of brain ADC histograms
Creators
- 1. Rijksuniversiteit Leiden (Netherlands). Dept. of Diagnostic Radiology
- 2. Leiden University Medical Center (Netherlands). Div. of Image Processing
- 3. MR Clinical Science, Best (Netherlands). Philips Medical Systems
- 4. University Coll., London (United Kingdom). Inst. of Neurology
- 5. Leiden University Medical Center (Netherlands). Div. of Medical Statistics
Description
The aim of this study was to assess the effect of differences in acquisition technique on whole-brain apparent diffusion coefficient (ADC) histogram parameters, as well as to assess scan-rescan reproducibility. Diffusion-weighted imaging (DWI) was performed in 7 healthy subjects with b-values 0-800, 0-1000, and 0-1500 s/mm2 and fluid-attenuated inversion recovery (FLAIR) DWI with b-values 0-1000 s/mm2. All sequences were repeated with and without repositioning. The peak location, peak height, and mean ADC of the ADC histograms and mean ADC of a region of interest (ROI) in the white matter were compared using paired-sample t tests. Scan-rescan reproducibility was assessed using paired-sample t tests, and repeatability coefficients were reported. With increasing maximum b-values, ADC histograms shifted to lower values, with an increase in peak height (p<0.01). With FLAIR DWI, the ADC histogram shifted to lower values with a significantly higher, narrower peak (p<0.01), although the ROI mean ADC showed no significant differences. For scan-rescan reproducibility, no significant differences were observed. Different DWI pulse sequences give rise to different ADC histograms. With a given pulse sequence, however, ADC histogram analysis is a robust and reproducible technique. Using FLAIR DWI, the partial-voluming effect of cerebrospinal fluid, and thus its confounding effect on histogram analyses, can be reduced
Additional details
Publishing Information
- Journal Title
- European Radiology
- Journal Volume
- 14
- Journal Issue
- 3
- Journal Page Range
- p. 425-430
- ISSN
- 0938-7994
- CODEN
- EURAE3
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 35031215
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- BIOMEDICAL RADIOGRAPHY; BRAIN; CEREBROSPINAL FLUID; DIFFUSION; FLUIDS; HEIGHT; PEAKS; PULSES
- Descriptors DEC
- BIOLOGICAL MATERIALS; BODY; BODY FLUIDS; CENTRAL NERVOUS SYSTEM; DIAGNOSTIC TECHNIQUES; DIMENSIONS; MATERIALS; MEDICINE; NERVOUS SYSTEM; NUCLEAR MEDICINE; ORGANS; RADIOLOGY