Radioisotope tracer study in trickle bed reactors
Creators
- 1. Indian Inst. of Technology, Dept. of Chemical Engineering, Delhi, Hauz Khas, New Delhi (India)
- 2. Bhabha Atomic Research Centre, Isotope Applications Div., Mumbai (India)
Description
The residence time distribution (RTD) of liquid phase in trickle bed reactors has been measured for air-water system using radioisotope tracer technique. Experiments were carried out in a glass column of internal diameter of 0.152 m packed with glass beads and actual catalyst particles of two different shapes. From the measured RTD curves, mean residence time of liquid was calculated and used to estimate liquid holdup. The axial dispersion model was used to simulate the experimental data and estimate mixing index, ie. Peclet number. The effect of liquid and gas flow rates on total liquid holdup and Peclet number has been investigated. Results of the study indicated that shape of the packing has significant effect on holdup and axial dispersion. Bodenstein number has been correlated to Reynolds number, Galileo number, shape and size of the packing. (author)
Additional details
Publishing Information
- Journal Title
- Canadian Journal of Chemical Engineering
- Journal Volume
- 79
- Journal Issue
- 6
- Journal Page Range
- p. 860-865
- ISSN
- 0008-4034
INIS
- Country of Publication
- Canada
- Country of Input or Organization
- Canada
- INIS RN
- 33053179
- Subject category
- S37: INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL CHEMISTRY;
- Descriptors DEI
- CATALYSTS; FLOW BLOCKAGE; FLUID FLOW; GAS FLOW; HYDRODYNAMICS; LIQUID FLOW; PACKED BEDS; REYNOLDS NUMBER; TRACER TECHNIQUES
- Descriptors DEC
- FLUID FLOW; FLUID MECHANICS; ISOTOPE APPLICATIONS; MECHANICS
Optional Information
- Notes
- 20 refs., 1 tab., 5 figs.