Heat transfer from a flat plate pasted on one end of a duct with an orifice in pressurized He II

  • 1. Kyoto Univ., Dept. of Energy Science and Technology, Uji, Kyoto (Japan)
  • 2. Kyoto Univ., Inst. of Advanced Energy, Uji, Kyoto (Japan)

Description

Steady state and transient heat transfer from a flat plate located at one end of a Gorter-Mellink duct with an orifice was measured for bulk liquid temperatures of 1.8 to 2.1 K at atmospheric pressure in order to clarify the heat flow expansion and contraction. One side of the test plate was attached to the end plate of the duct, and the other end of the duct was opened to pressurized He II. The open ratio of the orifice to the cross-sectional duct area was varied from 9% to 100%. The CHFs increased with the increase in the open ratio but almost independent of the orifice location in the duct. A CHF correlation that can express the experimental data within 15% error was given. Numerical analysis was also performed. (author)

Additional details

Publishing Information

Journal Title
Nippon Dennetsu Shinpojiumu Koen Ronbunshu
Journal Volume
41
Journal Issue
2
Journal Page Range
p. 401-402
CODEN
NDSRD4

Conference

Title
41. national heat transfer symposium of Japan
Dates
26-28 May 2004
Place
Toyama (Japan)

Optional Information

Notes
2 refs., 4 figs.