A gas cooling method of silicon strip detectors is presented. Based on it, a concept of a silicon vertex detector has been developed. Calculations of temperature distributions and mechanical deformation of a detector module have been performed with the help of Finite Elements Analysis. Results of thermal and mechanical measurements for a one-to-one dummy detector module cooled in air and helium are presented. ((orig.))
Additional details
Publishing Information
- Journal Title
- Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
- Journal Volume
- 348
- Journal Issue
- 1
- Journal Page Range
- p. 119-126.
- ISSN
- 0168-9002
- CODEN
- NIMAER
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- Netherlands
- INIS RN
- 26011771
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- AIR; DEFORMATION; DESIGN; FINITE ELEMENT METHOD; GAS COOLING; HELIUM; PERFORMANCE TESTING; POSITION SENSITIVE DETECTORS; SI SEMICONDUCTOR DETECTORS; SPATIAL RESOLUTION; TEMPERATURE DISTRIBUTION
- Descriptors DEC
- CALCULATION METHODS; COOLING; ELEMENTS; FLUIDS; GASES; MEASURING INSTRUMENTS; NONMETALS; NUMERICAL SOLUTION; RADIATION DETECTORS; RARE GASES; RESOLUTION; SEMICONDUCTOR DETECTORS; TESTING