This paper presents the conception principles retained in order to insure the function ''iodine trapping'' of the 1300 MWe light water reactor's ventilation systems. These principles are the following: treatment of the gaseous waste flow restricted to the building with iodine contamination risk; bypassing of the iodine traps in the case of normal reactor operation with the possibility of a quick tilting in the case of iodine risk; use of the heaters before the traps; use of iodine reloading traps; use of an important activated carbon thickness. Systems of ventilation, together with their iodine traps, are presented

Additional details

Additional titles

Original title (French)
Principes de conception retenus pour assurer la fonction ''piegeage des iodes'' des systemes de ventilation des reacteurs a eau legere du palier 1300 MWe

Publishing Information

Imprint Title
Seminar on the testing and operation of off-gas cleaning systems at nuclear facilities, Karlsruhe, Germany, F.R., 3-7 May 1982
Imprint Pagination
671 p.
Journal Page Range
p. 220-247.
Report number
IAEA-SR--72

Conference

Title
Seminar on the testing and operation of off-gas cleaning systems at nuclear facilities.
Dates
3-7 May 1982.
Place
Karlsruhe (Germany, F.R.).

Optional Information

Secondary number(s)