Accuracy and optimal timing of activity measurements in estimating the absorbed dose of radioiodine in the treatment of Graves' disease
- 1. Department of Mechanical and Industrial Engineering, University of Massachusetts, Amherst, MA 01003 (United States)
- 2. Department of Mathematics and Statistics, University of Massachusetts, Amherst, MA 01003 (United States)
- 3. U.O. Fisica Sanitaria, Azienda Ospedaliero-Universitaria Pisana, P.O. S.Chiara, via Roma n.67, 56125 Pisa (Italy)
- 4. School of Public Health and Health Sciences, University of Massachusetts, Amherst, MA 01003 (United States)
- 5. Department of Electrical and Computer Engineering, University of Massachusetts, Amherst, MA 01003 (United States)
Description
Calculation of the therapeutic activity of radioiodine 131I for individualized dosimetry in the treatment of Graves' disease requires an accurate estimate of the thyroid absorbed radiation dose based on a tracer activity administration of 131I. Common approaches (Marinelli-Quimby formula, MIRD algorithm) use, respectively, the effective half-life of radioiodine in the thyroid and the time-integrated activity. Many physicians perform one, two, or at most three tracer dose activity measurements at various times and calculate the required therapeutic activity by ad hoc methods. In this paper, we study the accuracy of estimates of four 'target variables': time-integrated activity coefficient, time of maximum activity, maximum activity, and effective half-life in the gland. Clinical data from 41 patients who underwent 131I therapy for Graves' disease at the University Hospital in Pisa, Italy, are used for analysis. The radioiodine kinetics are described using a nonlinear mixed-effects model. The distributions of the target variables in the patient population are characterized. Using minimum root mean squared error as the criterion, optimal 1-, 2-, and 3-point sampling schedules are determined for estimation of the target variables, and probabilistic bounds are given for the errors under the optimal times. An algorithm is developed for computing the optimal 1-, 2-, and 3-point sampling schedules for the target variables. This algorithm is implemented in a freely available software tool. Taking into consideration 131I effective half-life in the thyroid and measurement noise, the optimal 1-point time for time-integrated activity coefficient is a measurement 1 week following the tracer dose. Additional measurements give only a slight improvement in accuracy.
Availability note (English)
Available from http://dx.doi.org/10.1088/0031-9155/56/3/003Additional details
Identifiers
- DOI
- 10.1088/0031-9155/56/3/003;
- PII
- S0031-9155(11)65171-3;
Publishing Information
- Journal Title
- Physics in Medicine and Biology
- Journal Volume
- 56
- Journal Issue
- 3
- Journal Page Range
- p. 557-571
- ISSN
- 0031-9155
- CODEN
- PHMBA7
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 43023087
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ACCURACY; ALGORITHMS; BIOLOGICAL HALF-LIFE; DISEASES; DISTRIBUTION; DOSIMETRY; ERRORS; IODINE 131; NOISE; PATIENTS; RADIATION DOSES; REACTION KINETICS; SAMPLING; SCHEDULES; THERAPY; THERMODYNAMIC ACTIVITY; THYROID
- Descriptors DEC
- BETA DECAY RADIOISOTOPES; BETA-MINUS DECAY RADIOISOTOPES; BODY; DAYS LIVING RADIOISOTOPES; DOSES; ENDOCRINE GLANDS; GLANDS; INTERMEDIATE MASS NUCLEI; IODINE ISOTOPES; ISOTOPES; KINETICS; MATHEMATICAL LOGIC; MEDICINE; NUCLEI; ODD-EVEN NUCLEI; ORGANS; RADIOISOTOPES