Published November 1977
| Version v1
Report
Restricted
Master test plan for the MB-75 mW (B) generators
Description
Five 75 mW radioisotope thermoelectric generators (RTGs) and two electrically heated thermoelectrically heated generators (ETGs) are to be supplied under this contract. A facility is not available that can accommodate RTG mechanical shock and vibration testing and this testing will be performed on ETGs. The tests to be conducted will fall into four categories: (1) materials evaluation; (2) component evaluation; (3) ETG evaluation; and (4) RTG evaluation. The shock and vibration test procedures are described
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS., PC A03/MF A01.
Files
Additional details
Publishing Information
- Imprint Pagination
- 40 p.
- Report number
- GA-A--14717
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 9379391
- Subject category
- S07: ISOTOPES AND RADIATION SOURCES; S30: DIRECT ENERGY CONVERSION;
- Descriptors DEI
- IMPACT SHOCK; MECHANICAL VIBRATIONS; PERFORMANCE TESTING; PLUTONIUM 238; RADIOISOTOPE HEAT SOURCES; SIMULATION; THERMOELECTRIC GENERATORS
- Descriptors DEC
- ACTINIDE NUCLEI; ALPHA DECAY RADIOISOTOPES; DIRECT ENERGY CONVERTERS; ENERGY SOURCES; EVEN-EVEN NUCLEI; HEAVY NUCLEI; ISOTOPES; NUCLEI; PLUTONIUM ISOTOPES; RADIOISOTOPES; TESTING; YEARS LIVING RADIOISOTOPES