Is there a need for radiation quantities defined in the body of the individual?
Creators
- 1. Central Electricity Generating Board, Berkeley (UK). Berkeley Nuclear Labs.
Description
The ICRU, in Publication 39, defined quantities in terms of dose equivalent in standard tissue within the body of the individual. It has been suggested that these quantities cannot be precisely measured, and are in any event unnecessary since the value of the quantity can be taken to be equal to the reading of an approved dosemeter, calibrated on a standard phantom. It is argued in this paper that the ICRU quantities are useful because they can be applied to any body site in addition to those on the trunk. The suggested alternative approach would, for example, give significant errors if applied to intermediate energy neutron dosimetry of the extremities. At a more fundamental level, quantities defined in the body of the individual are needed for legal rigour, since rogue readings can never be eliminated entirely. (author)
Additional details
Publishing Information
- Journal Title
- Radiation Protection Dosimetry
- Journal Volume
- 28
- Journal Issue
- 1-2
- Series
- Radiat. Prot. Dosim.
- Journal Page Range
- 17-19
- ISSN
- 0144-8420
- CODEN
- RPDOD
Conference
- Title
- Seminar on the implementation of dose-equivalent operational quantities into radiation protection practice.
- Dates
- 7-9 Jun 1988.
- Place
- Braunschweig (Germany, F.R.).
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- United Kingdom
- INIS RN
- 21010433
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- CALIBRATION; DOSE EQUIVALENTS; DOSIMETRY; ICRU; LEGAL ASPECTS; MAN; RADIATION PROTECTION; STANDARDIZATION
- Descriptors DEC
- ANIMALS; INTERNATIONAL ORGANIZATIONS; MAMMALS; PRIMATES; VERTEBRATES
Optional Information
- Secondary number(s)
- CONF--8806266; EUR--12182.