Published December 1997 | Version v1
Report Restricted

Criteria for assembly of in vivo measuring systems using high-resolution γ-spectroscopy for evaluation of incorporated radionuclides

Creators

  • 1. GSF Forschungszentrum fuer Umwelt und Gesundheit, Neuherberg (Germany). Inst. fuer Strahlenschutz

Description

The paper reviews the available, fundamental measuring methods relying on γ-spectroscopy for their possible application in whole-body and partial-body counters for detection of manifold incorporation of radionuclides. Particular emphasis is placed on the response functions of various detectors, the assembly, the differentiated radioactivity distribution in the body, the various components of background activity and the corresponding suppression mechanisms, and possible ways of using the energy dependence for optimised detection of specific γ energies in a given body region. Criteria and relations as well as their advantages and drawbacks are discussed. (orig./CB)

Abstract (German)

Diese Arbeit prueft die zur Verfuegung stehenden grundlegenden, γ-spektroskopischen Messmethoden auf deren moegliche Anwendung im Spektrum der Ganz- und Teilkoerperzaehler zum Nachweis der mannigfach inkorporierten Radionuklide. Insbesondere wird eingegangen auf die Response Funktionen verschiedener Detektoren, die Anordnung, die differenzierte Aktivitaetsverteilung im Koerper, die verschiedenen Untergrundkomponenten und deren Unterdrueckungsmechanismen sowie die Beeinflussung durch die Energieabhaengigkeit zum optimalen Nachweis spezifischer γ-Energien an einem bestimmten Ort am Koerper. Kriterien und Relationen sowie deren Vor- und Nachteile werden diskutiert. (orig.)

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Part of:
High-resolution gamma spectroscopy with whole-body and partial-body counters. Experience, recommendations. Report

Additional details

Additional titles

Original title (German)
Kriterien zum Aufbau von In Vivo Messsystemen zur hochaufloesenden γ-Spektrometrie inkorporierter Radionuklide

Publishing Information

Imprint Title
High-resolution gamma spectroscopy with whole-body and partial-body counters. Experience, recommendations. Report
Imprint Pagination
102 p.
Journal Page Range
p. 11-18
Report number
VKTA--47

Conference

Title
High-resolution gamma spectroscopy with whole-body and partial-body counters - Experience, recommendations
Original Conference Title
Arbeitstagung: Hochaufloesende Gamma-Spektrometrie an Ganz- und Teilkoerperzaehlern - Erfahrungen, Empfehlungen
Acronym
Working meeting
Dates
5-6 Dec 1996
Place
Dresden (Germany)

Optional Information

Notes
Imprint:Hochaufloesende Gamma-Spektrometrie an Ganz- und Teilkoerperzaehlern. Erfahrungen, Empfehlungen. Bericht