Published September 1996 | Version v1
Journal article

Performance of the beam position monitor for the Advanced Photon Source

  • 1. Accelerator Systems Division, Advanced Photon Source, Argonne National Laboratory, Argonne, IL 60439 (United States)

Description

Performance measurement and analysis of the Advanced Photon Source (APS) beam position monitor (BPM) electronics are reported. The results indicate a BPM resolution of 0.16 μm·mA/√Hz in terms of the single-bunch current and BPM bandwidth. For the miniature insertion device (ID) BPM, the result was 0.1 μm·mA/√Hz. The improvement is due to the 3.6 times higher position sensitivity (in the vertical plane), which is partially canceled by the lower button signal by a factor of 2.3. The minimum single-bunch current required was roughly 0.03 mA. The long-term drift of the BPM electronics independent of the actual beam motion has measured at 2 μm/hr, which settled after approximately 1.5 hours. This drift can be attributed mainly to the temperature effect. Implications of the BPM resolution limit on the global and local orbit feedback systems for the APS storage ring will also be discussed. copyright 1996 American Institute of Physics

Additional details

Publishing Information

Journal Title
Review of Scientific Instruments
Journal Volume
67
Journal Issue
9
Journal Page Range
p. 3366-3367.
ISSN
0034-6748
CODEN
RSINAK

Conference

Title
synchrotron radiation instrumentation symposium; 7. users meeting for the advanced photon source (APS).
Acronym
SRI '95
Dates
16-20 Oct 1995.
Place
Argonne, IL (United States).

Optional Information

Secondary number(s)
CONF-9510119--.