Published 1991 | Version v1
Report Restricted

Bias in segmented gamma scans arising from size differences between calibration standards and assay samples

Description

Recent advances in segmented gamma scanning have emphasized software corrections for gamma-ray self-absorption in particulates or lumps of special nuclear material in the sample. Another feature of this software is an attenuation correction factor formalism that explicitly accounts for differences in sample container size and composition between the calibration standards and the individual items being measured. Software without this container-size correction produces biases when the unknowns are not packaged in the same containers as the calibration standards. This new software allows the use of different size and composition containers for standards and unknowns, an enormous savings considering the expense of multiple calibration standard sets otherwise needed. This report presents calculations of the bias resulting from not using this new formalism. The calculations may be used to estimate bias corrections for segmented gamma scanners that do not incorporate these advanced concepts. This paper describes this attenuation-correction-factor formalism in more detail and illustrates the magnitude of the biases that may arise if it is not used. 5 refs., 7 figs

Availability note (English)

MF available from INIS under the Report Number; OSTI as DE91014596; NTIS; INIS; US Govt. Printing Office Dep.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
6 p.
Report number
LA-UR--91-2082

Conference

Title
32. Institute of Nuclear Materials Management (INMM) annual meeting.
Dates
28-31 Jul 1991.
Place
New Orleans, LA (USA).

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
22091959
Subject category
S98: NUCLEAR DISARMAMENT, SAFEGUARDS AND PHYSICAL PROTECTION; S37: INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL CHEMISTRY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
ATTENUATION; CONTAINERS; CORRECTIONS; GAMMA FUEL SCANNING; GAMMA SPECTROSCOPY; NONDESTRUCTIVE ANALYSIS; NUCLEAR MATERIALS MANAGEMENT; S CODES; SAMPLING
Descriptors DEC
CHEMICAL ANALYSIS; COMPUTER CODES; FUEL SCANNING; MANAGEMENT; SPECTROSCOPY

Optional Information

Contract/Grant/Project number
Contract W-7405-ENG-36
Funding organization
USDOE, Washington, DC (USA).
Secondary number(s)
CONF-910774--1.