Bird screen meshes are installed at the air inlet and outlet ducts of spent fuel storage casks to inhibit the intrusion of debris from the external environment. The presence of these screens introduces an additional resistance to air flow through the ducts. In this study, a porous media model was developed to simplify the bird screen meshes. CFD analyses were used to derive and verify the flow resistance factors for the porous media model. Thermal analyses were carried out for concrete storage cask using the porous media model. Thermal tests were performed for concrete casks with bird screen meshes. The measured temperatures were compared with the analysis results for the porous model. The analysis results agreed well with the test results. The analysis temperatures were slightly higher than the test temperatures. Therefore, the reliability and conservatism of the analysis results for the porous model have been verified

Additional details

Publishing Information

Journal Title
Journal of Nuclear Fuel Cycle and Waste Technology
Journal Volume
16
Journal Issue
2
Series
5 refs, 10 figs, 6 tabs
Journal Page Range
p. 223-232
ISSN
1738-1894

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
49078554
Subject category
S42: ENGINEERING;
Descriptors DEI
AIR FLOW; COMPUTERIZED SIMULATION; FISSION PRODUCTS; FLUID MECHANICS; RELIABILITY; SIMULATION; SPENT FUEL CASKS; SPENT FUEL STORAGE; THERMAL ANALYSIS; VERIFICATION
Descriptors DEC
CASKS; CONTAINERS; FLUID FLOW; GAS FLOW; ISOTOPES; MATERIALS; MECHANICS; RADIOACTIVE MATERIALS; SIMULATION; STORAGE