Porous media modeling and verification of thermal analysis for inlet and out ducts of spent fuel storage cask
- 1. Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)
- 2. Chungnam National University, Daejeon (Korea, Republic of)
Description
Bird screen meshes are installed at the air inlet and outlet ducts of spent fuel storage casks to inhibit the intrusion of debris from the external environment. The presence of these screens introduces an additional resistance to air flow through the ducts. In this study, a porous media model was developed to simplify the bird screen meshes. CFD analyses were used to derive and verify the flow resistance factors for the porous media model. Thermal analyses were carried out for concrete storage cask using the porous media model. Thermal tests were performed for concrete casks with bird screen meshes. The measured temperatures were compared with the analysis results for the porous model. The analysis results agreed well with the test results. The analysis temperatures were slightly higher than the test temperatures. Therefore, the reliability and conservatism of the analysis results for the porous model have been verified
Additional details
Publishing Information
- Journal Title
- Journal of Nuclear Fuel Cycle and Waste Technology
- Journal Volume
- 16
- Journal Issue
- 2
- Series
- 5 refs, 10 figs, 6 tabs
- Journal Page Range
- p. 223-232
- ISSN
- 1738-1894
INIS
- Country of Publication
- Korea, Republic of
- Country of Input or Organization
- Korea, Republic of
- INIS RN
- 49078554
- Subject category
- S42: ENGINEERING;
- Descriptors DEI
- AIR FLOW; COMPUTERIZED SIMULATION; FISSION PRODUCTS; FLUID MECHANICS; RELIABILITY; SIMULATION; SPENT FUEL CASKS; SPENT FUEL STORAGE; THERMAL ANALYSIS; VERIFICATION
- Descriptors DEC
- CASKS; CONTAINERS; FLUID FLOW; GAS FLOW; ISOTOPES; MATERIALS; MECHANICS; RADIOACTIVE MATERIALS; SIMULATION; STORAGE