Light water reactor pressure isolation valve performance testing
Creators
- 1. Energy Technology Engineering Center, Canoga Park, CA (United States)
Description
The Light Water Reactor Valve Performance Testing Program was initiated by the NRC to evaluate leakage as an indication of valve condition, provide input to Section XI of the ASME Code, evaluate emission monitoring for condition and degradation and in-service inspection techniques. Six typical check and gate valves were purchased for testing at typical plant conditions (550F at 2250 psig) for an assumed number of cycles for a 40-year plant lifetime. Tests revealed that there were variances between the test results and the present statement of the Code; however, the testing was not conclusive. The life cycle tests showed that high tech acoustic emission can be utilized to trend small leaks, that specific motor signature measurement on gate valves can trend and indicate potential failure, and that in-service inspection techniques for check valves was shown to be both feasible and an excellent preventive maintenance indicator. Life cycle testing performed here did not cause large valve leakage typical of some plant operation. Other testing is required to fully understand the implication of these results and the required program to fully implement them. (author)
Availability note (English)
Available from INIS in electronic form
Files
Additional details
Publishing Information
- Imprint Pagination
- 108 p.
- Report number
- NUREG/CR--5515
INIS
- Country of Publication
- United States
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 34002230
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- IN-SERVICE INSPECTION; LEAK TESTING; PERFORMANCE TESTING; RELIEF VALVES; SAFETY STANDARDS; SYSTEM FAILURE ANALYSIS; US NRC; WATER COOLED REACTORS
- Descriptors DEC
- CONTROL EQUIPMENT; EQUIPMENT; FLOW REGULATORS; INSPECTION; NATIONAL ORGANIZATIONS; REACTORS; STANDARDS; SYSTEMS ANALYSIS; TESTING; US ORGANIZATIONS; VALVES
Optional Information
- Notes
- 5 refs, 82 figs, 12 tabs
- Funding organization
- Nuclear Regulatory Commission, Washington, DC (United States)
- Secondary number(s)
- ETEC--88--01