Published August 2012 | Version v1
Report

Tests of the pressure drop related characteristic during cooling by natural convection of the fast breeder reactor plants

Description

The purpose of this study is to confirm the heat transfer characteristics of the air cooler (AC) of the Fast Breeder Reactor (FBR) which has a function to remove the residual heat of the reactor by heat exchange between sodium and air in natural convection region if electric power would be lost. In order to confirm the characteristics of the AC installed in the FBR plant, the heat transfer test by using the AC which is installed in the sodium test loop owned by Toshiba Corporation has been planned. In this study, the heat transfer characteristic tests will be performed by using the AC in sodium test loop, and the CFD analyses will be performed to evaluate the test results. In addition, the elemental tests to confirm the influence of the heat transfer tube placement by using the heat transfer tube of the same specification as the AC of Monju will be performed. (author)

Part of:
Annual safety research report, JFY 2011

Additional details

Publishing Information

Imprint Title
Annual safety research report, JFY 2011
Imprint Pagination
604 p.
Journal Page Range
p. 547-553
Report number
JNES-RE--2012-0001-Rev.2

Optional Information

Notes
2 refs., 5 figs., 1 tab.; This record replaces 45112127