Published November 2017 | Version v1
Journal article

Preliminary comparison of the registration effect of 4D-CBCT and 3D-CBCT in image-guided radiotherapy of Stage IA non–small-cell lung cancer

  • 1. Department of Radiation Oncology, Sichuan Cancer Hospital (China)
  • 2. Shenzhen Hospital of Southern Medical University, #1333 Xinhu Road, Bao'an District, Department of Oncology, Shenzhen 518110, Guangdong Province (China)
  • 3. Shenzhen Hospital of Southern Medical University, #1333 Xinhu Road, Bao'an District, Department of Rehabilitation, Shenzhen 518110, Guangdong Province (China)
  • 4. Shenzhen Hospital of Southern Medical University, #1333 Xinhu Road, Bao'an District, Department of Oncology and Hematology, Shenzhen 518110, Guangdong Province (China)

Description

In this study, we compared the registration effectiveness of 4D cone-beam computed tomography (CBCT) and 3D-CBCT for image-guided radiotherapy in 20 Stage IA non–small-cell lung cancer (NSCLC) patients. Patients underwent 4D-CBCT and 3D-CBCT immediately before radiotherapy, and the X-ray Volume Imaging software system was used for image registration. We performed automatic bone registration and soft tissue registration between 4D-CBCT or 3D-CBCT and 4D-CT images; the regions of interest (ROIs) were the vertebral body on the layer corresponding to the tumor and the internal target volume region. The relative displacement of the gross tumor volume between the 4D-CBCT end-expiratory phase sequence and 4D-CT was used to evaluate the registration error. Among the 20 patients (12 males, 8 females; 35–67 years old; median age, 52 years), 3 had central NSCLC and 17 had peripheral NSCLC, 8 in the upper or middle lobe and 12 in the lower lobe (maximum tumor diameter range, 18–27 mm). The internal motion range in three-dimensional space was 12.52 ± 2.65 mm, accounting for 47.8 ± 15.3% of the maximum diameter of each tumor. The errors of image-guided registration using 4D-CBCT and 3D-CBCT on the x (left–right), y (superior–inferior), z (anterior–posterior) axes, and 3D space were 0.80 ± 0.21 mm and 1.08 ± 0.25 mm, 2.02 ± 0.46 mm and 3.30 ± 0.53 mm, 0.52 ± 0.16 mm and 0.85 ± 0.24 mm, and 2.25 ± 0.44 mm and 3.59 ± 0.48 mm (all P < 0.001), respectively. Thus, 4D-CBCT is preferable to 3D-CBCT for image guidance in small pulmonary tumors because 4D-CBCT can reduce the uncertainty in the tumor location resulting from internal motion caused by respiratory movements, thereby increasing the image-guidance accuracy.

Availability note (English)

Available from http://dx.doi.org/10.1093/jrr/rrx040; Available from http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5710603

Additional details

Identifiers

Publishing Information

Journal Title
Journal of Radiation Research
Journal Volume
58
Journal Issue
6
Journal Page Range
p. 854-861
ISSN
0449-3060

INIS

Country of Publication
Japan
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
49049962
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
COMPUTER CODES; COMPUTERIZED TOMOGRAPHY; LUNGS; NEOPLASMS; PATIENTS; RADIOTHERAPY; X RADIATION
Descriptors DEC
BODY; DIAGNOSTIC TECHNIQUES; DISEASES; ELECTROMAGNETIC RADIATION; IONIZING RADIATIONS; MEDICINE; NUCLEAR MEDICINE; ORGANS; RADIATIONS; RADIOLOGY; RESPIRATORY SYSTEM; THERAPY; TOMOGRAPHY

Optional Information

Copyright
Copyright (c) The Author 2017. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Radiation Oncology.
Notes
PMCID: PMC5710603; PMID: 28992047; PUBLISHER-ID: rrx040; OAI: oai:pubmedcentral.nih.gov:5710603