Assessing cumulative dose distributions in combined radiotherapy for cervical cancer using deformable image registration with pre-imaging preparations
Creators
- 1. Department of Radiation Oncology, Saitama Medical University, International Medical Center, 1397-1 Yamane, Hidaka-shi, 350-1298 (Japan)
- 2. Gunma Prefectural Cancer Center, 617-1 Takabayashinishi-machi, Ohta-shi, Gunma 373-8550 (Japan)
- 3. Gunma University Heavy Ion Medical Center, 3-39-22 Showa-machi, Maebashi-shi, Gunma 371-8511 (Japan)
- 4. Department of Radiation Oncology, Gunma University, 3-39-22 Showa-machi, Maebashi-shi, Gunma 371-8511 (Japan)
Description
The purpose of the study was to evaluate the feasibility of deformable image registration (DIR) in assessing cumulative dose distributions of the combination of external beam radiotherapy (EBRT) and fractionated intracavitary brachytherapy (ICBT) for cervical cancer. Three-dimensional image data sets of five consecutive patients were used. The treatment plan consisted of whole pelvic EBRT (total dose: 45 Gy in 25 fractions) combined with computed tomography (CT)-based high-dose rate ICBT (≥24 Gy in 4 fractions to the high risk clinical target volume (HR-CTV)). Organs at risk and HR-CTV were contoured on each CT images and dose-volume parameters were acquired. Pre-imaging preparations were performed prior to each ICBT to minimize the uncertainty of the organ position. Physical doses of each treatment were converted to biologically equivalent doses in 2 Gy daily fractions by the linear quadratic model. Three-dimensional dose distributions of each treatment were accumulated on CT images of the first ICBT using DIR with commercially available image registration software (MIM Maestro®). To compare with DIR, 3D dose distributions were fused by rigid registration based on bony structure matching. To evaluate the accuracy of DIR, the Dice similarity coefficient (DSC) was measured between deformed contours and initial contours. The cumulative dose distributions were successfully illustrated on the CT images using DIR. Mean DSCs of the HR-CTV, rectum, and bladder were 0.46, 0.62 and 0.69, respectively, with rigid registration; and 0.78, 0.76, and 0.87, respectively, with DIR (p <0.05). The mean DSCs derived from our DIR procedure were comparable to those of previous reports describing the quality of DIR algorithms in the pelvic region. DVH parameters derived from the 2 methods showed no significant difference. Our results suggest that DIR-based dose accumulation may be acceptable for assessing cumulative dose distributions to assess doses to the tumor and organs at risk in combined radiotherapy for cervical cancer under pre-imaging preparations
Availability note (English)
Available from http://dx.doi.org/10.1186/s13014-014-0293-4; Available from http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4296553Additional details
Identifiers
Publishing Information
- Journal Title
- Radiation Oncology (Online)
- Journal Volume
- 9
- Journal Page Range
- vp.
- ISSN
- 1748-717X
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 47066247
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- BIOMEDICAL RADIOGRAPHY; BRACHYTHERAPY; CALORIMETRY; COMPUTER CODES; COMPUTERIZED TOMOGRAPHY; DOSE EQUIVALENTS; EXTERNAL BEAM RADIATION THERAPY; GY RANGE 01-10; GY RANGE 10-100; HAZARDS; IMAGES; NEOPLASMS; RADIATION DOSE DISTRIBUTIONS
- Descriptors DEC
- ABSORBED DOSE RANGE; DIAGNOSTIC TECHNIQUES; DISEASES; GY RANGE; MEDICINE; NUCLEAR MEDICINE; RADIATION DOSE RANGES; RADIOLOGY; RADIOTHERAPY; THERAPY; TOMOGRAPHY
Optional Information
- Copyright
- Copyright (c) Abe et al.
- Notes
- PMCID: PMC4296553; PMID: 25526986; PUBLISHER-ID: 293; OAI: oai:pubmedcentral.nih.gov:4296553; licensee BioMed Central. 2014